Application: This cable is suitable for connecting electrical equipment indoor. It should be used in dry and humid locations.
Construction:
1.Conductor - Copper : Class 5 fine stranded according to EN 60228
2.Insulation - Polyvinylchloride (PVC)
3.Outher sheath - Polyvinylchloride (PVC)
Standards: EN 50525-2-11/2011
Core identification: Accordance to HD 308 standard.
Electrical Performance:
Nominal Voltage: 300 / 500 Volt
Test Voltage [V]AC 2000
Short circuit time max. [sec] 5
Bending radius in motion x diameter 5
Temperature range: -5°C till +90°C
Operating temperature: short circuit 150°C
Flammability: Accordance to EN 60332-1-2 - Eca